Shanghai Qilong High Pressure Container Co., Ltd.

High quality, Best service, Reasonable price

 

Home
Products
About Us
Factory Tour
Quality Control
Contact Us
Request A Quote
Home ProductsMedical Oxygen Regulator

Flow Meter Health Care Digital Medical Oxygen Tank Regulator / Medical Gas Regulators

Certification
Good quality Medical Gas Cylinder for sales
Good quality Medical Gas Cylinder for sales
I wish to continue to lead the industry development of Qilong to first-class quality and service, the customer is committed to innovation and upgradin

—— Luca Burlando

Sincerely bless Qilong more brilliant tomorrow, with innovative writing Qilong gorgeous, I wish the future Qilong Zaipan peak.

—— William

I'm Online Chat Now

Flow Meter Health Care Digital Medical Oxygen Tank Regulator / Medical Gas Regulators

China Flow Meter Health Care Digital Medical Oxygen Tank Regulator  / Medical Gas Regulators supplier
Flow Meter Health Care Digital Medical Oxygen Tank Regulator  / Medical Gas Regulators supplier Flow Meter Health Care Digital Medical Oxygen Tank Regulator  / Medical Gas Regulators supplier

Large Image :  Flow Meter Health Care Digital Medical Oxygen Tank Regulator / Medical Gas Regulators

Product Details:

Place of Origin: China
Brand Name: TWA
Certification: DOT
Model Number: YR-86-29

Payment & Shipping Terms:

Minimum Order Quantity: Negotiate
Price: Negotiate
Packaging Details: Carton
Delivery Time: 15-20days
Supply Ability: 100000 Piece/Pieces per Month
Contact Now
Detailed Product Description
Medium: Oxygen Inlet Connection: G5/8'-RH(M)
Output Connection Screw Threda: 8mm Mettering Range (L/min): 1-10or 1-15
MAX.discharge Pressure :: 0.2-0.3MPa Outer Connection: Nasal Oxygen Cannula
Accuracy:: Grade 4
High Light:

oxygen tank regulator

,

o2 cylinder regulator

        Medical Oxygen Regulator Buoy Type Oxygen Inhalator YR-86-29
        specifications:
 
 
 

Name Digital medical OxyEn Regulator With Flow Meter Health Care Product
Type YR-86-29
Gas O2
Input pressure 15MPa
Output pressure 0.2 ~ 0.3MPa
Flow control range 1-10L/Min , 1-15L/Min
valve pressure range 0.35 ± 0.05Mpa
Output connection screw thread 8mm
Valve material Brass
Pressure gauge 50mm
Bottle material PVB
Humidifier capacity 200ml
delivery time 15-25 days

       
  Application:

Medical regulator is used for oxygen breathing in hospital

        

Type Medium

Mettering range
(L/min)

Accuracy

Entrance
Pressure
(MPa)

Exit
pressure(MPa)

Entrance connection screw threda Output connection screw threda
YR-86(A) O2 1-10or 1-15 grade4

12MPa
 

0.2-0.3MPa

G5/8-14-RH
CGA540-RH
G3/4-14-RH

8mm


Description:

welding regulator, for oxygen, we also have other types of regulators for ,acetylene,
ARGON,CO2 gases

1. Forged brass body; bonnet for maximum strength.
2. Oxygen safety relief valve is set for safe operation.
3. Sintered metal inlet filter to trap impurities.
4. No soldered joints, for easy maintenance.
5. Easy to read dual scale gauges (BAR/P.S.I) with virtually unbreakable crew-on lean lens
6. Gauges meet EN 562 and BAM approved dual scale (Bar/Psi) and marked for maximum
working pressure.
7. Models are available for 200 or 300 Bar Max. inlet pressure.




Mainly function :
Oxygen flow range:1-10L/Min 1-15L/Min
Pressure reducing range:2.0-3.0kg
Relief valve pressure range :(3.5kg+0.5kg
Appliance introduction :
1. Before using ,please fill pour clear water into moisture bottle about one third reaching water
ine site.
2. DF-2 blind nut straw into bolt head ,make the pipe of flow meter square water line.
3. Put off regulator (9),put on oxygen tube switch ,so you will the data from needle position of pressure gauge (2).At last ,straw flow on/off at anti-clock wise accroding to patients need,
adjust switch.
4. If patient need oxygen for a long time ,can use nose pipe to help patient absorb oxygen.
5. Moisture bottle(20) circles at clockwise,adjust (17)oxygen hole to other site.
Attention point :
1. Before using the suction ,you will check all parts bad or good and clean it by drying choth .
2. Pressure gauge (2),regulator(3) no oil ,otherwise explode.
3. Clearwater in moistyre bottle keeps clean.
4. There is adjustable nut(6) in the front of plunder shall be straw at clockwise .
5. Relief value(7)(15) keeps out of danger.
6. Oxygen dosage is decided by doctor.
7. After using suction,put off the oxygen tube switch,make rest oxygen out,pressure gage to
zero site,last put off flow switch if using again,first put on the oxygen tube switch,avoid
exploding.
8. The product must be examined periodical,at least once every 6 month.

Packaging & Shipping:
About packing: Annual package
About our shipping:
1. The parts normally will be shipped out within 30 working days after the payment
confirmed.
2. The parts can also be shipped by DHL/TNT/UPS/EMS/FedEx, you are welcome to
choose the way you like.
3. We are not responsible for any accidents, delays or other issues caused by the forwarder.
4. Any import fees or charges are afforded by buyers.

Advantage:

1. Low MOQ: It can meet your promotional business very well.
2. OEM Accepted: We can produce any your design.
3. Good Service: We treat clients as friend.
4. Good Quality: We have strict quality control system .Good reputation in the market.
5. Fast & Cheap Delivery: We have big discount from forwarder (Long-term Contract).

Flow Meter Health Care Digital Medical Oxygen Tank Regulator  / Medical Gas Regulators    

Flow Meter Health Care Digital Medical Oxygen Tank Regulator  / Medical Gas Regulators

Contact Details
Shanghai Qilong High Pressure Container Co., Ltd.

Contact Person: Rachel

Send your inquiry directly to us (0 / 3000)